GD-5208 Rapid Equilibrium Closed Cup Flash Point Tester

Last Update
20 / 07 / 2021
MinimumPurchase
1
Visited
11 Times

Price
CALL

Share

Add To Cart

Attention!

This company is registered as a Free Member. Avoid making payments before meeting the seller or seeing the goods in person. COD (Cash On Delivery) or meeting directly with the seller is a safe transaction method that we recommend.

Specification of GD-5208 Rapid Equilibrium Closed Cup Flash Point Tester

Browse through the extensive list of Environmental Laboratory Equipment. Find the best offer from thousand of supplier in Indonetwork.
alat laboratorium lingkungan

GD-5208 Rapid Equilibrium Closed Cup Flash Point Tester Summary This instrument is designed and made as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can meet the requirements of rapid determination for closed cup flash point of petroleum products in oil,chemical, varnish, paint, railway, aviation, electricity, commercial inspection and science research institution. This instrument is specially suitable to determine different kinds of colored paints,oil paints, adhesives,solvents and petroleum products which the closed cup flash point is -30℃~50℃.The instrument is also correspond with ISO1523 and ISO3679.
I. Main technical features 1.Designed as per GB/T 5208-2008 Determination of flash point - Rapid equilibrium closed cup method. It can realize purpose of testing closed cup flash point rapidly and at low temperature. 2.The instrument adopts semiconductor refrigeration device and external water cooling device.The size is small and cooling rate is rapid.Easy to operate. 3.Test sample needed is less. 2ml for each time(4ml for solid sample and semi-solid sample) 4.The determination procedure is automatically completed except ignition.Test results can be printed automatically. II. Main technical specifications 1.Flash point measuring range: -30℃~+50℃; 2. Precision of determination:it meets the standard GB/T 5208; 3. Temperature resolution:±0.1℃; 4. Igniting device:Electric igniting gun 5. Cooling mode:Semiconductor(with cold water cycle at external connection) 6. Igniting source: gas,LPG(or other civilian fuels) 7. Power supply:AC(220±10%)V,50Hz 8. Total power consumption:≦300W; 9. Ambient temperature:5℃~30℃ Relative humidity:(30~80)% 10. Dimension:490mm×520mm×390mm 11. Net weight: 25.5kg.
Show More

PT. MITRA KATIGA SEJAHTERA

Dengan hormat,

Kami adalah perusahaan swasta nasional yang bergerak di bidang Agent tunggal dan Distributor serta Suplier peralatan laboratorium kualitas air dan udara, adapun peralatan yang kami jual :

I. Peralatan Laboratorium Kualitas Udara:

A) STAPLEX USA ( AGENT TUNGGAL )

- TFIA Series High Volume Air Samplers
- Filter Papers, Filter Holders, Tripod
- Calibration Kits, Outdoor Shelters, Flow Adjuster/ Brush Seater
- Constant Flow Controllers, Flow Recorders
- Carrying/ Storage Cases, Timers, Impactors, Size Selective Inlets
- TSP and PM10 Environmental Air Sampling Systems
- Radioiodine Air Sampling Systems, Low Volume Air Sampers
- Area, Asbestos and Microbial Air Samplers, Personal Air Samplers

B) NOVA ( AGENT TUNGGAL INDONESIA)

- Portable Four Gas Air Analyzer
- Portable Single Gas Air Analyzer

C) ASSEMBLAD ( DISTRIBUTOR INDONESIA)

- Gas analyzers
- Smoke meters

D) DELTAOHM ( AGENT TUNGGAL INDONESIA)

-Temperature
- Humidity
- Pressure
- Air Speed
- Light
- Air Quality - CO - CO2
- Multifunction
- Dataloggers
- Photometry-Radiometry
- Acoustic - Vibrations
- Microclimate - WBGT
- Environmental Analysis & Water Analysis
- Temperature Probes
- Vibration Analyzer Hand Harm and Wole Body

E) SHINAGAWA ( DISTRIBUTOR INDONESIA)

- Wet Gas Meter
- Dry Gas Meter

F) HAZ-DUST ( DISTRIBUTOR INDONESIA)

- Epam 5000 Environmental Particulate Air Monitor
- Particulate Air Monitor
- Personal Dust Monitor
- Particulate Sensing System
- Wireless Video Dust Monitoring System

G) CASTLE( DISTRIBUTOR INDONESIA)

- Sound Level Meter
- Noise Activated Systems
- Audiometer
- Vibration Meter
- Air Sampling

H) KIMO ( DISTRIBUTOR)

- Anemometer
- Datalogger
- Displayer
- Dosimeter
- Flowmeter
- Hygrometer
- Luxmeter
- Micromanometer
- Multifunction
- Pitot tube, Portables, Sensor
- Solarimeter
- Sound Level Meter
- Tachometer
- Temperature probe
- Thermometer
I) E-INSTRUMENT ( DISTRIBUTOR INDONESIA)

- HVAC Combustion Analyzers
- Portable Emissions Analyzers
- Indoor Air Quality

J) ANAPOL ( DISTRIBUTOR INDONESIA)

- Flue Gas Analyzer

K) AIRMETRICS ( DISTRIBUTOR INDONESIA)

- MiniVol Portable Air Sampler

L) MIR ( Medical International Research DISTRIBUTOR)

- Spirometers and Oximeters

II. Peralatan Laboratorium Kualitas Air :

A) AQUALYTIC ( DISTRIBUTOR INDONESIA)

- Photometers
- COD-Equipment
- BOD-Measurement
- Turbidity Meters
- Hand-held-Meters
- Rapid Tests
- Comparator
- Flocculation
- Powder Dispenser
- Cabinets

B) Sandberg & Schneidewind
- Trawas ( Water Testing Kit)

C) WILDCO ( DISTRIBUTOR INDONESIA)

- Horizontal Alpha Water Sampler
- Vertical Alpha Water Sampler

D) PARTECH ( DISTRIBUTOR INDONESIA)

- Portable Suspended Solids Monitoring

E) TOA DKK ( DISTRIBUTOR INDONESIA)

- Water Quality Checker
- Ion meter
Show More

PT. MITRA KATIGA SEJAHTERA

Free
Ruko Cibubur Indah Blok A no 29 Jakarta Timur - Jakarta Timur, DKI Jakarta, Indonesia -13730
Last Login 10 / 05 / 2022